With world-class data centre facilities located in nearby Santa Clara and Sunnyvale, CenturyLink supports businesses in San Francisco. Our data centres are expertly designed for optimal flexibility, connectivity, security and power, so Bay Area companies are well-positioned for innovation and growth.

Learn how the Santa Clara and Sunnyvale , California data centres can serve your business.

Announcements

Take a Virtual Tour of our CH3 Data Centre

Data Centres

San Francisco Data Centre Locations

Locations

SC4: Santa Clara, CA

Space: 167,932 sf   Power: 8 MW

Tech Specs

SC4: Santa Clara     Space: 167,932 sf     Power: 8 MW

Real Estate Summary

  • Located near San Jose and San Francisco International Airports; 10 minutes from San Jose, 35 minutes from San Francisco, CA
  • Two story building
  • Total building interior (sf) = 167,932
  • Raised floor (inches) = 12

Electrical Summary

  • Santa Clara provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 8 MW
  • Minimum two fuel replenishing company

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilises two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N +1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

SC5: Santa Clara, CA

Space: 103,940 sf   Power: 8 MW

Tech Specs

SC5: Santa Clara     Space: 103,940 sf     Power: 8 MW

Real Estate Summary

  • Located near San Jose and San Francisco International Airports; 10 minutes from San Jose, 35 minutes from San Francisco, CA
  • One story building
  • Total building interior (sf) = 103,940
  • Raised floor (inches) = 18

Electrical Summary

  • Santa Clara provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 8 MW
  • Minimum one fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilises two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N + 1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

SC8: Santa Clara, CA

Space: 90,139 sf   Power: 10 MW

Tech Specs

SC8: Santa Clara     Space: 90,139 sf     Power: 10 MW

Real Estate Summary

  • Located near San Jose Airport; 10 minutes from San Jose, CA
  • One story building
  • Total building interior (sf) = 90,139
  • Raised floor (inches) = 30 

Electrical Summary

  • Santa Clara provides power feeds
  • Power density minimum(W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 10 MW
  • Minimum one fuel replenishing companies 

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilises two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N + 1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard 

SC9: Santa Clara, CA 

Space: 124,383 sf   Power: 10 MW

Tech Specs

SC9: Santa Clara     Space: 124,383 sf     Power: 10 MW

Real Estate Summary

  • Located near San Jose Airport; 10 minutes from San Jose, CA
  • One story building
  • Total building interior (sf) = 124,383
  • Raised floor (inches) = 36 

Electrical Summary

  • Santa Clara provides power feeds
  • Power density minimum (W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 10 MW
  • Minimum one fuel replenishing companies

Fire Detection and Suppression Summary

  • VESDA provides early warning detection
  • Pre-Action system utilises two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N + 1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

SN1: Sunnyvale, CA 

Space: 76,573 sf   Power: 6 MW

Tech Specs

SN1: Sunnyvale     Space: 76,573 sf     Power: 6 MW

Real Estate Summary

  • Located near San Jose and San Francisco International Airports; 10 minutes from San Jose and 35 minutes from San Francisco, CA
  • One story building
  • Total building interior (sf) = 76,573
  • Raised floor (inches) = 24 

Electrical Summary

  • PG&E provides power feeds
  • Power density minimum(W/sf) = 150
  • Generator configuration = N + 1
  • Total Power Capacity = 6 MW
  • Minimum one fuel replenishing company 

Fire Detection and Suppression Summary

  • Pre-Action system utilises two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N + 1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

SN2: Sunnyvale, CA

Space: 24,000 sf   Power: 2 MW

Tech Specs

SN2:   Sunnyvale     Space:   24,000 sf     Power:   2 MW

Real Estate Summary

  • Located near San Jose and San Francisco International Airports; 10 minutes from San Jose and 35 minutes from San Francisco, CA
  • One story building
  • Total building interior (sf) = 24,000
  • Raised floor (inches) = 18 

Electrical Summary

  • PG&E provides power feeds
  • Power density minimum(W/sf) = 150
  • Generator configuration = 2N
  • Total Power Capacity = 2 MW
  • Minimum two fuel replenishing companies 

Fire Detection and Suppression Summary

  • Pre-Action system utilises two detection methods; one ionized and one photo electric detector interlocked with the dry pipe sprinkler system

Mechanical Summary

  • Cooling system configuration = N + 1
  • CenturyLink manages temperature and humidity to strict ASHRAE standard

More Locations 

Over 60 Data Centre Locations Worldwide

Latest from the EpiCenter Blog

Discussing the Data Centre of the Future

Michael Levy | March 13,2017

Many children grow up with toys you'd expect: bicycles, stuffed animals, dolls, building blocks, etc. It wouldn't be surprising to find a Magic-8 Ball in their arsenal that gives them ambiguous answers to the many seemingly important questions in childhood. … Read more…→ The post Discussing the Data Centre of the Future appeared first on CenturyLink EpiCenter Blog.

Operational Excellence: By the Book

David Meredith | March 07,2017

This article was previously published in Forbes Voice. Many large technology products come with a handbook when purchased. For example, if you buy a new large-screen television, the box in which it comes typically includes a handbook on how to … Read more…→ The post Operational Excellence: By the Book appeared first on CenturyLink EpiCenter Blog.

Operational Excellence: The Key to Safeguarding Your IT Infrastructure

Kelly Sullivan | March 01,2017

Technology can streamline mundane tasks, enable people to more easily keep in contact with family and friends around the world and allow TV shows and movies to be viewed almost anytime and anywhere. However, when it doesn't work correctly, it … Read more…→ The post Operational Excellence: The Key to Safeguarding Your IT Infrastructure appeared first on CenturyLink EpiCenter Blog.

CenturyLink
Business
@CenturyLink ENT

Resources

Get Started with Featured Resources and Tools

Get Started
Request Consultation

Request Consultation

Call Us

Call Us

SALES: +65 6768 8098 
SUPPORT: +65 6768 8099

Get Connected. See What's Next for Business.